TEL:+86 132 6656 7067
3-year warranty
Technical Support
100% detection
Spot stock
Tel:+86 132 6656 7067
Online Consultation
PLC Ratio :1×2~1×128/ 2×2~2×128; Optional Connector FC/SC/LC/BARE | |||
| CL-PLC-A-1×*-FC-* | CL-PLC-A-2×*-FC-* | CL-PLC-A-1×*-LC-* | CL-PLC-A-2×*-LC-* |
![]() | ![]() | ![]() | ![]() |
| CL-PLC-A-1×*-SC-* | CL-PLC-A-2×*-SC-* | CL-PLC-A-1×*-B-* | CL-PLC-A-2×*-B-* |
![]() | ![]() | ![]() | ![]() |
| 1×2 ~ 1x128 PLC Splitter Specification: | ||||||||||||||||||||||||
| Category | 1×2 | 1x3 | 1×4 | 1x6 | 1×8 | 1x12 | 1×16 | 1x24 | 1×32 | 1x48 | 1×64 | 1×128 | ||||||||||||
| Operating wavelength | 1260nm-1650nm | |||||||||||||||||||||||
| Fiber category | G657A | |||||||||||||||||||||||
| Insert Loss (dB) Max | 3.8 | 6.1 | 7.1 | 9 | 10.2 | 12.5 | 13.5 | 15.5 | 16.5 | 18.4 | 20.2 | 23.8 | ||||||||||||
Uniformity (dB) Max | 0.4 | 0.4 | 0.6 | 1.6 | 0.8 | 1.2 | 1.2 | 1.5 | 1.5 | 2 | 2 | 2.5 | ||||||||||||
| Polarization Dependent Loss (dB) | 0.2 | 0.2 | 0.2 | 1.2 | 0.2 | 0.25 | 0.25 | 0.3 | 0.3 | 0.4 | 0.4 | 0.4 | ||||||||||||
| Refection Loss (dB) Max | 55 | 55 | 55 | 55 | 55 | 55 | 55 | 55 | 55 | 55 | 55 | 55 | ||||||||||||
| Directivity (dB) Max | 55 | 55 | 55 | 55 | 55 | 55 | 55 | 55 | 55 | 55 | 55 | 55 | ||||||||||||
| Wavelength Dependent Loss (dB) | 0.5 | 0.5 | 0.5 | 1.5 | 0.5 | 0.8 | 0.8 | 0.8 | 0.8 | 1 | 1 | 1.2 | ||||||||||||
| Temperature Stability -40 ℃~85 ℃ (dB) Max | 0.5 | 0.5 | 0.5 | 1.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | ||||||||||||
| Operation temperature (℃) | -40~85 | |||||||||||||||||||||||
| Storage temperature (℃) | -40~85 | |||||||||||||||||||||||
| Mini-Tube Size (mm) (L×W×H) | 60×7×4 | 60×12×4 | 80×20×6 | 100×40×6 | 100×40×6 | N/A | ||||||||||||||||||
| ABS Size (mm) (L×W×H) | 100×80×10 | 120×80×18 | 140×115×18 | |||||||||||||||||||||
Remarks: The parameters above excluded the loss of fiber connectors; At least, 0.2dB loss will be added per each connector in fiber channel.
| 1×2 ~ 1x128 PLC Splitter Specification: | |||||||||||||||||||||
| Category | 2×2 | 2×4 | 2×8 | 2×16 | 2×32 | 2×64 | 2×128 | ||||||||||||||
| Operating wavelength(nm) | 1260nm-1650nm | ||||||||||||||||||||
| Fiber category | G657A | ||||||||||||||||||||
| Insert Loss (dB) Max | 4.2 | 7.6 | 10.5 | 13.8 | 17 | 20.8 | 24.5 | ||||||||||||||
| Uniformity (dB) Max | 0.9 | 1.1 | 1.2 | 1.5 | 1.8 | 2.2 | 2.5 | ||||||||||||||
| Polarization Dependent Loss (dB) Max | 0.2 | 0.2 | 0.3 | 0.3 | 0.4 | 0.4 | 0.4 | ||||||||||||||
| Reflection Loss (dB) Max | 55 | 55 | 55 | 55 | 55 | 55 | 55 | ||||||||||||||
| Directivity (dB) Max | 55 | 55 | 55 | 55 | 55 | 55 | 55 | ||||||||||||||
| Wavelength Dependent Loss (dB) Max | 0.5 | 0.5 | 0.5 | 0.8 | 0.8 | 1 | 1.2 | ||||||||||||||
| Temperature Stability -40~85 ℃ (dB) | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | ||||||||||||||
| Operate temperature (℃) | -40~85 | ||||||||||||||||||||
| Storage temperature (℃) | -40~85 | ||||||||||||||||||||
| Mini-Tube Size (mm) (L×W×H) | 60×7×4 | 80×12×4 | 80×20×6 | N/A | |||||||||||||||||
| ABS Size (mm) (L×W×H) | 100×80×10 | 120×80×18 | 140×115×18 | ||||||||||||||||||
Remarks: The parameters above excluded the loss of fiber connectors; At least, 0.2dB loss will be added per each connector in fiber channel.
C-LIGHT ABS PLC Splitter is a planar lightwave circuit splitter housed in a durable ABS enclosure for efficient optical signal distribution in fiber optic networks. It evenly divides an input optical signal into multiple output channels and supports splitting ratios from 1×2 to 1×128 and 2×2 to 2×128. With 1260–1650nm operating wavelength, G657A fiber, stable optical performance, and a wide operating temperature range of -40°C to +85°C, the ABS PLC Splitter is suitable for FTTH, PON, data center, and other fiber distribution applications.
The ABS PLC Splitter supports configurations from 1×2 to 1×128 and 2×2 to 2×128, providing flexible options for different fiber distribution requirements.
With an operating wavelength range of 1260–1650nm, the splitter supports major fiber access wavelengths used in modern PON and FTTx networks.
PLC technology provides controlled optical power distribution between output channels, helping maintain consistent signal levels across the splitter ports.
The splitter uses G657A fiber to provide reliable optical performance and support practical fiber routing in compact distribution environments.
The splitter is designed for operation from -40°C to +85°C, allowing deployment across a wide range of indoor and outdoor environmental conditions.
The ABS enclosure provides a lightweight and durable package with resistance to impact and corrosion for long-term fiber network deployment.
1×N configurations distribute one optical input into multiple output channels and are widely used for centralized optical signal distribution in PON and FTTH networks.
2×N configurations provide two optical inputs and multiple outputs for network architectures requiring dual-input fiber signal distribution.
C-LIGHT provides FC, SC, LC, and bare-fiber configurations, allowing the splitter to match different installation and connection requirements.
The ABS package is available in different housing sizes according to the selected splitting ratio and fiber configuration, supporting compact and high-density installation.
PLC waveguide technology provides controlled optical splitting performance, with insertion loss depending on the selected splitting ratio and configuration.
The splitter is designed to maintain stable performance across polarization conditions, supporting consistent optical signal distribution.
The product specification provides return loss values up to 55dB, helping maintain stable optical performance in fiber network systems.
Temperature stability is maintained across the -40°C to +85°C operating range, helping reduce optical performance variation in changing environments.
ABS PLC Splitters distribute optical signals from the PON network toward multiple subscriber connections, making them an important component in FTTH access networks.
The splitter supports passive optical network architectures by providing efficient point-to-multipoint optical signal distribution without requiring active equipment at the splitting point.
The compact ABS package can be integrated into fiber distribution and termination equipment where multiple optical outputs need to be organized in a limited space.
Selected splitting configurations can be used in optical distribution environments where compact packaging and high-density fiber connectivity are required.
The standard ABS PLC Splitter provides a broad splitting ratio range and multiple housing sizes, making it suitable for general fiber distribution and higher-capacity PON deployments.
The Mini ABS PLC Splitter uses a more compact ABS package and is better suited to space-constrained installations such as fiber distribution boxes, terminal enclosures, and compact outdoor panels.
Multiple splitting ratios and connector options make it easier to select a configuration according to the optical distribution architecture.
The ABS enclosure and -40°C to +85°C operating range support stable deployment across demanding indoor and outdoor fiber network environments.
Each splitter is fully tested before delivery to help ensure consistent optical performance and product reliability.
C-LIGHT provides a 3-year warranty, technical support, long-term maintenance, and professional guidance for fiber network deployment.
An ABS PLC Splitter is a passive optical splitter based on planar lightwave circuit technology and packaged in an ABS enclosure. It divides one or more optical input signals into multiple output channels.
C-LIGHT ABS PLC Splitter supports 1×2 to 1×128 and 2×2 to 2×128 configurations, covering a wide range of optical distribution requirements.
The splitter operates across 1260–1650nm, making it suitable for a broad range of fiber access and PON network applications.
C-LIGHT provides FC, SC, LC, and bare-fiber options for different fiber connection and installation requirements.
The specified operating temperature range is -40°C to +85°C, supporting deployment in a wide variety of environmental conditions.
It is commonly used in FTTH, PON systems, fiber distribution boxes, optical access networks, data centers, and other applications requiring passive optical signal splitting.
C-LIGHT ABS PLC Splitter provides a flexible solution for passive optical signal distribution, with splitting ratios from 1×2 to 1×128 and 2×2 to 2×128, multiple connector options, G657A fiber, and stable operation from -40°C to +85°C. Its durable ABS housing and wide configuration range make it suitable for FTTH, PON, and high-density fiber distribution applications.
Contact Us●100% of products pass initial test, final test and factory inspection.
●3-step quality control management process.
●100% complete implementation of customer order quality requirements.
●100% guarantee of customer product data information security.

Please contact us to download the certification certificate.

Please Note: Installing a third party transceiver does not void your network equipment warranty. Network equipment manufacturers all have guidelines stating that warranty support on their products will not be affected.
Get expert advice quickly,Meet your requirements in all aspects
Phone:+86 132 6656 7067
Email : sales@c-light.com